INSPECTING CONDOMINIUM BUILDINGS AND UNITS What We Do Our typical pre-purchase inspection of a condominium apartment unit includes a detailed inspection of the interior of the unit to the ASHI® Standards of Practice and the CAHPI (BC) Standards of Practice and a general "walkthrough" of selected accessible common areas of the complex. These may include the underground parking area, the mechanical or boiler room, the general exterior and the roof (if access is provided). The common area "walkthrough" is not designed to generate an all-inclusive list of building flaws but is meant to enable the inspector to comment on building design features which tend to result in problems as well as the general level of building maintenance. The information gathered may suggest follow-up questions for clients to ask the vendor of the property, the strata council or the property manager. We strongly recommend that all available information about the building in question regarding past or present problems and planned major expenditures be obtained. The "Leaky Condo Syndrome" Many three and four story wood frame multi-family buildings in the lower mainland of British Columbia suffer what has come to be known as the "leaky condo syndrome". This syndrome is characterized by rot damage to wooden components of the building as a result of water infiltration and possibly internally generated moisture. The cost to correct the damage and repair the building to a point where such damage is unlikely to re-occur can be very high. There have been many cases where individual owners of condominium units have received assessments in the tens of thousands as their share of the repair costs. There are also an increasing number of multi-story apartment buildings of concrete construction in which problems relating to moisture have been identified. Until relatively recently it was generally believed that most "high-rise" condominium apartment buildings were at low risk for damage caused by water infiltration. As more invasive testing is being carried out on such buildings it is being discovered that many have leak problems resulting in significant damage. Their exposure to wind-driven rain makes all exterior components (especially windows) vulnerable to leaks if not adequately constructed. As with low rise wood frame condominiums the cost of correction can be significant. A typical home inspection is a visual inspection and does not involve disassembling building components or carrying out invasive testing such as drilling holes to allow the use of moisture meters to check for building leaks. Because there is often no visual evidence of the type of leaking which causes the "leaky condo syndrome" this type of leaking and its attendant damage may go undetected during a home inspection. — James Dobney Inspections a division of 510308 BC Ltd. Suggestions for Condo Buyers
Standards of Practice of The Canadian Association of Home and Property Inspectors (BC) Table of Contents 1. INTRODUCTION 1.1 The Canadian Association of Home and Property Inspectors British Columbia (CAHPI(BC)) is a not-for-profit professional society established in 1991. Membership in CAHPI (BC) is voluntary and its members include private, fee-paid home inspectors. CAHPI(BC)'s objectives include promotion of excellence within the profession and continual improvement of its members' inspection services to the public. 2. PURPOSE & SCOPE 2.1 The purpose of these Standards of Practice is to establish a minimum and uniform standard for private, fee-paid home inspectors who are members of the Canadian Association of Home and Property Inspectors British Columbia. Inspections performed to these Standards of Practice are intended to provide the client with information regarding the condition of the systems and components of the strata unit as inspected at the time of the inspection. 2.2 The Inspector shall: A. inspect:
A. including other inspection services, systems or components in addition to those required by these Standards of Practice. B. specifying repairs, provided the inspector is appropriately qualified and willing to do so. C. excluding systems and components from the inspection if requested by the client. → Back to Table of Contents 3. STRUCTURAL SYSTEM 3.1 The inspector shall: A. inspect:
A. inspect any structural elements located in common areas B. provide any engineering service or architectural service. C. offer an opinion as to the adequacy of any structural system or component. 3.3 The inspector may:
4. EXTERIOR 4.1 The exterior is common area and is not inspected. 4.2 The inspector is NOT required to: A. inspect:
→ Back to Table of Contents 5. ROOF SYSTEM 5.1 The roofing and related elements are common area and are not inspected. 5.2 The inspector is NOT required to: A. inspect:
→ Back to Table of Contents 6. PLUMBING SYSTEM 6.1 For plumbing system elements located within the subject strata unit the inspector shall: A. inspect:
A. inspect:
7. ELECTRICAL SYSTEM 7.1 For electrical system elements located within the subject strata unit the inspector shall: A. inspect:
A. inspect:
→ Back to Table of Contents 8. HEATING SYSTEM 8.1 For heating system elements located within the subject strata unit the inspector shall: A. inspect:
A. inspect:
→ Back to Table of Contents 9. AIR CONDITIONING SYSTEMS 9.1 For air conditioning elements located within the subject strata unit the inspector shall: A. inspect the installed equipment. B. describe:
A. inspect central air conditioning physical plant. B. inspect electronic air filters. C. determine cooling supply adequacy or distribution balance. → Back to Table of Contents 10. INTERIOR 10.1 The inspector shall: A. inspect:
A. inspect:
→ Back to Table of Contents 11. INSULATION AND VENTILATION 11.1 For insulation and ventilation elements located within the subject strata unit the inspector shall: A. inspect:
A. inspect insulation or vapour retarders located in common areas. B. disturb insulation or vapour retarders. C. determine indoor air quality. → Back to Table of Contents 12. FIREPLACES AND SOLID FUEL BURNING APPLIANCES 12.1 For fireplaces and solid fuel burning appliances located within the subject strata unit the inspector shall: A. inspect:
A. inspect:
C. determine draft characteristics. D. move fireplace inserts or stoves or firebox contents. → Back to Table of Contents 13. GENERAL LIMITATIONS AND EXCLUSIONS 13.1 General limitations: A. Inspections performed in accordance with these Apartment Style Strata Title Standards of Practice:
A. The inspector is not required to perform any action or make any determination unless specifically stated in these Standards of Practice, except as may be required by lawful authority. B. Inspectors are NOT required to determine:
2002 CAPHI (BC) Apartment Style Condominium Standards of Practice → Back to Table of Contents 14. GLOSSARY OF TERMS Alarm Systems Warning devices, installed or free-standing, including but not limited to: carbon monoxide detectors, flue gas and other spillage detectors, security equipment, ejector pumps and smoke alarms. Apartment Style Strata Title A strata title condominium unit located in a building typically with other units above or below and sharing common structural, exterior and roofing elements and common areas as well as physical plant. Architectural Service Any practice involving the art and science of building design for construction of any structure or grouping of structures and the use of space within and surrounding the structures or the design for construction, including but not specifically limited to, schematic design, design development, preparation of construction contract documents, and administration of the construction contract. Automatic Safety Controls Devices designed and installed to protect systems and components from unsafe conditions. Component A part of a system. Decorative Ornamental; not required for the proper operation of the essential systems and components of a home. Describe To report a system or component by its type or other observed significant characteristics to distinguish it from other systems or components. Dismantle To take apart or remove any component, device or piece of equipment that would not be taken apart or removed by a homeowner in the course of normal and routine home owner maintenance. Engineering Service Any professional service or creative work requiring engineering education, training, and experience and the application of special knowledge of the mathematical, physical and engineering sciences to such professional service or creative work as consultation, investigation, evaluation, planning, design and supervision of construction for the purpose of assuring compliance with the specifications and design, in conjunction with structures, buildings, machines, equipment, works or processes. Further Evaluation Examination and analysis by a qualified professional, tradesman or service technician beyond that provided by the home inspection. Home Inspection The process by which an inspector visually examines the readily accessible systems and components of a home and which describes those systems and components in accordance with these Standards of Practice. Household Appliances Kitchen, laundry, and similar appliances, whether installed or free-standing. Inspect To examine any accessible systems or component of a building in accordance with these Standards of Practice, using normal operating controls and opening readily openable access panels. Inspector A person hired to examine any system or component of a building in accordance with these Standards of Practice. Installed Attached such that removal requires tools. Normal Operating Controls Devices such as thermostats, switches or valves intended to be operated by the homeowner. Readily Accessible Available for visual inspection without requiring moving of personal property, dismantling, destructive measures, or any action which will likely involve risk to persons or property. Readily Openable Access Panel A panel provided for homeowner inspection and maintenance that is readily accessible, within normal reach, can be removed by one person, and is not sealed in place. Recreational Facilities Spas, saunas, steam baths, swimming pools, exercise, entertainment, athletic, playground or other similar equipment and associated accessories. Report To communicate in writing. Representative Number One component per room for multiple similar interior components such as windows and electric receptacles; one component on each side of the building for multiple similar exterior components. Roof Drainage Systems Components used to carry water off a roof and away from a building. Significantly Deficient Unsafe or not functioning. Shut Down A state in which a system or component cannot be operated by normal operating controls. Solid Fuel Burning Appliances A hearth and fire chamber or similar prepared place in which a fire may be built and which is built in conjunction with a chimney; or a listed assembly of a fire chamber, its chimney and related factory-made parts designed for unit assembly without requiring field construction. Structural Component A component that supports non-variable forces or weights (dead loads) and variable forces or weights (live loads). System A combination of interacting or interdependent components, assembled to carry out one or more functions. Technically Exhaustive An investigation that involves dismantling, the extensive use of advanced techniques, measurements, instruments, testing, calculations or other means. Underfloor Crawl Space The area within the confines of the foundation and between the ground and the underside of the floor. Unsafe A condition in a readily accessible, installed system or component which is judged to be a significant risk of personal injury during normal, day-to-day use. The risk may be due to damage, deterioration, improper installation or a change in accepted residential construction standards. Wiring Methods Identification of electrical conductors or wires by their general type, such as "non-metallic sheathed cable" ("Romex"), "armoured cable" ("bx") or "knob and tube", etc. → Back to Table of Contents 2002 CAPHI (BC) Apartment Style Condominium Standards of Practice CAHPI(BC) Standards must be presented in their entirety and may not be altered or revised to include business logos or names! 2003 Revised Jan. 9,2003 |